Аргинин.Ру - всё об аргинине  
В начало
Контакты
Рекламодателям
 


молекула L-arginine
молекула L-arginine

Нобелевские лауреаты 1998 года:

Ф.Ферчготт

Л.Игнарро

Ф.Мурад

аргинин по 1000 мг 90 капсул производства Solgar

Про аргинин:

Что такое аргинин?
Откуда берется аргинин?
Механизм действия.

Аргинин в медицине:

Сердечная недостаточн.
Стенокардия
Гипертония
Онкология (рак)
Геронтология (старение)
Атеросклероз
Травмы
Ожоги
Гормональный обмен
ВИЧ/СПИД

Где купить аргинин

аргинин по 1000 мг 90 капсул производства Solgar

Библиотека статей:




Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; SAPE_base has a deprecated constructor in /home/ih72672/public_html/arginine.ru/1152e72650d4093c1a42c7534a7d7797/sape.php on line 21

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; SAPE_client has a deprecated constructor in /home/ih72672/public_html/arginine.ru/1152e72650d4093c1a42c7534a7d7797/sape.php on line 615

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; SAPE_context has a deprecated constructor in /home/ih72672/public_html/arginine.ru/1152e72650d4093c1a42c7534a7d7797/sape.php on line 1177

Deprecated: Methods with the same name as their class will not be constructors in a future version of PHP; SAPE_articles has a deprecated constructor in /home/ih72672/public_html/arginine.ru/1152e72650d4093c1a42c7534a7d7797/sape.php on line 1529

Warning: Use of undefined constant _SAPE_USER - assumed '_SAPE_USER' (this will throw an Error in a future version of PHP) in /home/ih72672/public_html/arginine.ru/1152e72650d4093c1a42c7534a7d7797/sape.php on line 1090
Авторы:Mochizuki S, Himi N, Miyasaka T, Nakamoto H, Takemoto M, Hirano K, Tsujioka K, Ogasawara Y, Kajiya F.
Дата:2002 год, май.

Evaluation of basic performance and applicability of a newly developed in vivo nitric oxide sensor.

  автоматический перевод
Direct measurement of nitric oxide (NO) is of great importance and value for both in vitro and in vivo studies on dynamic NO bioactivity. Here, we evaluated the basic performance of a newly developed NO sensor (Innovative Instruments, Inc.). Unlike other NO sensors, the new NO sensor has a highly durable, gas-permeable coating and is affected much less by electrical interference due to its integrated structure where working and reference electrodes are combined in a single element. Calibration with NO gas showed high sensitivity of about 580 pA per nmol-NO l(-1) (the detection limit 0.08 nmol-NO l(-1), S/N = 3). This sensor also showed high selectivity (25,000 times and more) to NO, compared with NO-related reagents such as L-arginine, N(G)-monomethyl-L-arginine, acetylcholine, nitroglycerin (NTG) and tetrahydrobiopterin as well as dissolved oxygen. As an in vivo application, the sensor was located in the anaesthetized rat abdominal aorta to measure NTG-derived plasma NO. lntra-aortic infusion of 0.5 mg NTG caused a measurable increase in plasma NO level (2.0 +/- 2.2 nmol l(-1), mean +/- SD, n = 3). In conclusion, the new NO sensor demonstrated a satisfying performance for both in vitro and in vivo applications.   Прямые измерения оксида азота (NO), имеет большое значение и ценность для обоих в vitro и в живом исследования по динамическому NO bioactivity. Здесь мы оценили основные показатели по новым NO датчик (новые инструменты, Inc). В отличие от других датчиков, NO, NO новый датчик обладает высокой долговечностью, газо-проницаемые покрытия, и пострадавших гораздо меньше, на электрических помех из-за своей структуры, в которых работает и ведения электродов объединены в единый элемент. Калибровка с NO газа показала высокую чувствительность около 580 пА за нмоль-NO л (-1) (предел обнаружения 0,08 нмоль-NO л (-1), S / N = 3). Этот датчик также показали высокую избирательность (25000 раз и более) для NO, по сравнению с NO-связанных реактивов таких, как L-аргинина, N (G)-monomethyl-L-аргинина, ацетилхолина, нитроглицерина (NTG), и tetrahydrobiopterin а также распущен кислорода. Как в живом применения, датчик был расположен в anaesthetized крыса брюшной аорты измерить NTG-на основе плазмы NO. lntra-aortic вливания 0,5 мг NTG привело к измерению увеличение в плазме NO уровне (2,0 + / - 2,2 нмоль л (-1), значит + / - УР, п = 3). В заключение следует отметить, что новый сенсор NO продемонстрировал хорошие показатели для обоих в vitro и в живом приложений.

к списку статей за 2002 год (en)

в библиотеку